available for Intravenous Therapy. |
|
of the OPIT Source Book Contact the OPIT Source Book |
|
|
|
|||||||||||||||||
|
|
|
|||||||||||||||||
|
|
||||||||||||||||||
|
|
||||||||||||||||||
|
|
|
|||||||||||||||||
|
|
New from Repro-Med, the Freedom60 Syringe Infusion System is designed for ambulatory infusions. Using standard 60cc syringes, calibrated rate-control tubing sets, and a patented constant-force mechanical pump, the Freedom60 provides features important to both patient and medical professional. The Freedom60 pump is portable, lightweight, easy-to-maintain, and requires no batteries. The system is simple to use and convenient. The Freedom60 provides very accurate flow rates and safe infusion pressures. A choice of rate-control tubing flow rates and syringe filling provides the pharmacist flexibility in choosing dosage amount and delivery time. The low cost of the Freedom60 System is attractive even when compared to the cost of standard gravity systems. | |||||||||||||||||
|
|
||||||||||||||||||
|
|
||||||||||||||||||
![]()
|
![]() Introducing the new Freedom60 Syringe Infusion System, engineered to liberate you and your patients from the problems of troublesome infusions, confining gravity systems, complicated electronics and high labor and supply costs. Never before has a low cost system provided so much performance, safety and convenience. |
(1) Ref: Drug stability and Compatibility Special
Considerations for Home Care, H.A. Lima, R.Ph., Infusion, August
1996, pp 10-16
(2) Ref: Aspects ofPressure Build-up in the Ue of Electronic Infusion
Devices, M.B. Stuheier, Anasth Intensivthe, August 1997, pp 185-190
(3) Ref: Cost ComparisonofFour Intermediate Intravenous Systems
for Homecare Use, S. Broucek, R.Ph., American Society of Health-System
Pharmacists, November 1996.
|
|
|
|
|
| PERFORMANCE | |
| Accuracy |
Consistent dose time for patient Less site complications (irritation) |
| Constant fluid pressure 13.5 psi | Less site complications Maintains flow at differing heights vs. site Clinical max. recommended is 15 psi (1) |
| Manual power | No batteries to maintain No "power-out" during dose |
| Molded ABS plastic pump housing | Light (14 oz.) & rugged Easily cleaned |
| 60cc syringe (polypropylene) | Longer storage than PVS bags (2) Extremely durable container (no punctures) |
| SAFETY | |
| Extension set safety-disc and rate label | Assures correct tubing & specific flow Aids in proper handling of connector |
| Recessed positive START switch | No inadvertet shutoff |
| Spring loaded syringe holder | Maintains proper orientation and prevents inadvertent removal
during dosing. Protects set end (at syringe) from impact |
| 60cc syringe (polypropylene) | Improved stability and compatibility vs. PVC bags and elastometric containers. |
| CONVENIENCE | |
| Size (12" x 2" , 4") | Low profile on tabletop Easy to store, convenent to carry Can be "worn" with pouch |
| Clear-view syringe shield | Easy to check mechanism position Prevents mishandling of syringe plunger |
| Syringe gradations (cc's) | Easy to verify operation Easy to verify remaining dose time Easy to verify contents at FULL or EMPTY |
| Syringe & controls orientation (top facing) | Easy to view syringe gradations Crank, switch, and syringe visible Operates flat on table, seat, or patient's lap |
| Large handle and crank | Easy to hold or carry pump Can be "hung" on bed, chair, cart, etc. Ergonomic crank (reduce effort) |
| Standard 60cc syringe | Standard filling Fill range 10cc - 60cc Easier to instruct patient Easier to purge air Included with set, easier purchasing |
| 60cc syringe (polypropylene) | Easier storage than PVC bags Less refrigeration or freezing required Easy to view contents (clarity) |
| Removable extension sets | Easy filling Multi-dosing Multiple fixed flow sets (60 & 120 cc/hr) |
| Multiple fixed flow sets (60 & 120 cc/hr) | Range of delivery time rates |
| Recessed positive START switch | Simple 1 button operation |
| Pump/syringe interface design | Simple 2 step set-up (load & start) Simple 2 step syringe removal (crank & remove) |
| COST/REIMBURSEMENT | |
| Inexpensive reuseable pump | Low capital cost (just pennies per start) Medicare code K0417, revenue $14 0- $21/day |
| Minimal pump maintenance | Lowers operating costs |
| Low cost set | Low cost per start |
|
|